METROLOGIC INSTRUMENTS, INC. MS2220 StratosS™ Scanner / Avery Scale Installation and User’s Guide

Seite 2

4 INTRODUCTION REPLACEMENT PARTS REPLACEMENT PARTS Part # Description Caution Window types (Diamonex and Sapphire) are not interchangeable due

Seite 3 - ABLE OF CONTENTS

5INTRODUCTION GENERAL PRECAUTIONS The following are some general precautions to remember when handling your MS2220 Scanner/Avery Scale. DO NO

Seite 4

6 INTRODUCTION MS2220 SCANNER/AVERY SCALE DESIGN SPECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power:

Seite 5

7INTRODUCTION MS2220 SCANNER/AVERY SCALE DESIGN SPECIFICATIONS Design Specifications Scale Capacities Capacity: kg unit 15 kg lb. unit 30.0

Seite 6

8 BASE MODEL CHARACTERISTICS MS2220 Scanner/Avery Scale Components Figure 7. MS2220 Components

Seite 7

9BASE MODEL CHARACTERISTICS MS2220 Scanner/Avery Scale Components ITEM NO. DESCRIPTION OF ITEM IN FIGURE 7 1 Scale Zero Button (see page 41

Seite 8

10 BASE MODEL CHARACTERISTICS MS2220 Scanner/Avery Scale Dimensions Figure 8. MS2220 Dimensions Specifications are subject to change without

Seite 9

11BASE MODEL CHARACTERISTICS MS2220 Scanner/Avery Scale Caution and Serial Number Labels Figure 10. MS2220 Label Locations (Top) and Examples

Seite 10 - INTRODUCTION

12 INSTALLATION QUICK INSTALLATION OUTLINE The following is a quick preview of the steps required for 1st time installations. Each item is disc

Seite 11

13INSTALLATION SITE REQUIREMENTS Service Access When routing and installing the cable(s) and power supply, make sure you leave access that the

Seite 12

Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may

Seite 13

14 INSTALLATION UNPACKING THE UNIT 1. Make sure the shipping box is top-side up before opening. 2. Remove the accessories box and check t

Seite 14 - BASE MODEL CHARACTERISTICS

15INSTALLATION UNPACKING THE UNIT MS2220 Package Warning All hardware securing the scale arms during shipping must be removed or the scale will

Seite 15

16 INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2220 Mounting Diagram Figure 16. MS2220 Mounting Diagram Specifications are subject to c

Seite 16

17INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 The following steps describe how to properly install the cables for an RS232 Strato

Seite 17

18 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 11. Configure the StratosS to match the host system’s RS232 parameters. Refer to

Seite 18 - INSTALLATION

19INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB The following steps describe how to properly install the cables for a Full

Seite 19

20 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB 10. Configure the StratosS to match the host system’s USB parameters. F

Seite 20 - UNPACKING THE UNIT

21INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB xx** Specifies international connection. See the Base Kit Components

Seite 21

22 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) IBM 46XX The following steps describe how to properly install the cables for an IBM 46xx

Seite 22

23INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) IBM 46XX 10. Configure the StratosS to match the host system’s IBM 46xx parameters. For

Seite 23

iiTABLE OF CONTENTS INTRODUCTION Manual Scope ...

Seite 24

24 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) OCIA The following steps describe how to properly install the cables for an OCIA Stratos

Seite 25 - NSTALLATION

25INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) OCIA 10. Configure the StratosS to match the host system’s OCIA parameters. Refer to the

Seite 26

26 INSTALLATION CABLE INSTALLATION (SECONDARY METROLOGIC SCANNER) The following steps describe how to properly install the cables between a second

Seite 27

27INSTALLATION CABLE INSTALLATION (SECONDARY METROLOGIC SCANNER) † See Aux power notes on page 26 See Power Source caution statement located

Seite 28

28 INSTALLATION EAS DEACTIVATION SW1 and SW2 are the switch banks inside the Checkpoint device that set the deactivation range. The following is

Seite 29

29SCANNER OPERATION SCAN ZONE Figure 24. Checker-Side (13 mil) Figure 25. Horizontal Left/Right (13 mil) Specifications are subject to ch

Seite 30

30 SCANNER OPERATION SCAN ZONE Figure 26. Horizontal Direct (13 mil) Figure 27. Vertical Direct (13 mil) Specifications are subject to ch

Seite 31

31SCANNER OPERATION IR ACTIVATION AREA (IR LED OUTPUT) The StratosS’s default power save mode† is Dual Action Power Save Mode #2 (see page 38).

Seite 32

32 SCANNER OPERATION INDICATOR DESCRIPTIONS Audible When in operation the StratosS provides audible feedback that indicates the status of the u

Seite 33

33SCANNER OPERATION INDICATOR DESCRIPTIONS Visual White and blue LEDs are located near the bottom corner of the vertical output window on the

Seite 34

iiiTABLE OF CONTENTS SCANNER OPERATION Scan Zone...

Seite 35 - SCANNER OPERATION

34 SCANNER OPERATION INDICATOR DESCRIPTIONS Failure Modes Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced

Seite 36

35SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display There is a two-digit error code display located under horizontal output

Seite 37

36 SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE DESCRIPTION 06 COMMUNICATION ERROR – The RS232 data line is b

Seite 38 - INDICATOR DESCRIPTIONS

37SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE DESCRIPTION 25 LASER #2 (RIGHT HORIZONTAL) HIGH CURRENT WARNI

Seite 39

38 SCANNER OPERATION POWER SAVE MODES The MS2220 has five configurable power save modes. Refer to the MetroSelect Configuration Guide for additi

Seite 40

39SCANNER OPERATION BEEPER OPTIONS AND BUTTON FUNCTIONS Changing the Beeper Tone Beeper tones may be configured incrementally using the following

Seite 41

40 SCANNER OPERATION STARTUP When the scanner first receives power the white LED will flash, the blue LED will turn on and the scanner will beep

Seite 42

41SCALE OPERATION SCALE ZEROING After the unit has been officially calibrated (see page 42) the scale can be re-zeroed by pressing the scale zero

Seite 43

42 SCALE OPERATION CALIBRATION The scanner/scale must be calibrated if:  it is a first time installation  the scale cannot be re-zeroed  t

Seite 44

43SCALE OPERATION CALIBRATION Priming the Scale for Calibration (lbs. or kg) Prime the scale before starting either method of calibration. Cal

Seite 45

ivTABLE OF CONTENTS SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections...

Seite 46

44 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display 1. Temporarily Remove the platter and place it in a

Seite 47 - SCALE OPERATION

45SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display 4. Enter full service access mode. Power down the

Seite 48

46 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display 7. Make sure there is no load on the scale platter.

Seite 49

47SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display 12. Remove the remaining half load from the scale t

Seite 50

48 SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display The following calibration procedure can be used when the

Seite 51 - CALIBRATION

49SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display 4. Enter the scale program mode. Power down the unit and

Seite 52

50 SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display 7. Make sure there is no load on the scale platter. The

Seite 53

51SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display 11. Remove half of the load and center the remaining load.

Seite 54

52 SCALE OPERATION CALIBRATION VERIFICATION U.S. Pounds (lbs.) The following tests verify if the scale's Calibration is accurate. For Kilo

Seite 55

53SCALE OPERATION CALIBRATION VERIFICATION Kilograms (kg) The following tests verify if the scale's Calibration is accurate. For US Poun

Seite 57

54 SCALE OPERATION SECURITY SEAL INSTALLATION The certification of the weighing mechanism of the scale version of this scanner is subject to fed

Seite 58

55SCALE OPERATION SECURITY SEAL INSTALLATION Wire Security Seal (Seal Conversion Kit 46-00239) 1. Temporarily remove the platter and place it

Seite 59

56 MAINTENANCE HORIZONTAL SCAN WINDOW REPLACEMENT Figure 67. Platter/Horizontal Scan Window Replacement * See replacement parts on page 4.

Seite 60

57MAINTENANCE VERTICAL SCAN WINDOW REPLACEMENT (MLPN 46-00232) Figure 68. Vertical Scan Window Replacement DAILY MAINTENANCE Smudges and d

Seite 61

58 TROUBLESHOOTING The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to

Seite 62 - MAINTENANCE

59TROUBLESHOOTING Symptom Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan (the white LED

Seite 63

60 TROUBLESHOOTING Symptom Possible Cause(s) Solution RS232 Only The com port at the host is not working or is not configured properly. The cabl

Seite 64 - TROUBLESHOOTING

61TROUBLESHOOTING RS232 DEMONSTRATION PROGRAM If an RS232 scanner is not communicating with your IBM compatible PC, key in the following BASIC

Seite 65

62 DEFAULT SETTINGS COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is, enabled or disabled. The sc

Seite 66

63DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB RSS Expanded Enable 9 9 9 9 Expanded ID “]e0” * 9

Seite 67

1INTRODUCTION MANUAL SCOPE This guide provides an overview of the MS2220 StratosS scanner/Avery scale operation with detailed information about

Seite 68 - DEFAULT SETTINGS

64 DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Dual Action Power Save Mode #1 9 9 9 9 Dual Actio

Seite 69

65DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Transmit UK Plessey Check Digit 9 9 9 9 EAN 128 En

Seite 70

66 DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Recv “i” = Transmit Scanner ID Byte 9 STX Prefix

Seite 71

67DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Two Digit Redundancy 9 9 9 9 Five Digit Redundancy

Seite 72

68 DEFAULT SETTINGS COMMUNICATION PARAMETERS Default settings for “Aux” interface The secondary scanner and the MS2220 series always communicate

Seite 73

69SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS The MS2220 Series scanner interfaces terminate to 10-pin modular jacks located on th

Seite 74

70 SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS Scanner to Host, IBM 46xx Scanner to Host, RS232 Pin Function Pin Functio

Seite 75 - SCANNER PINOUT CONNECTIONS

71SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS RS232 Interface Cable, MLPN 57-57210x-N-3 Pin Function** 1 No Connect 2 RS232 T

Seite 76

72 SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS Aux Port Configuration Cable*, MLPN 57-57008x-N-3 Pin Function** 1 No Connect

Seite 77 - MLPN 57-57016x-N-3

73REGULATORY COMPLIANCE SAFETY ITE Equipment IEC 60950-1; EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN: 60825-1:1994+A1+A2 Cau

Seite 78 - 10-Position Modular Plug

2 INTRODUCTION OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES Part # Description 57-57210x-N-3 RS232 Interface Cable Straight, 3.7 m (12') Cord

Seite 79 - REGULATORY COMPLIANCE

74 REGULATORY COMPLIANCE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Class A Devices The following

Seite 80

75REGULATORY COMPLIANCE EMC Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when

Seite 81

76 LIMITED WARRANTY The MS2200 StratosS ™ Series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS2200

Seite 82 - LIMITED WARRANTY

77PATENTS Patent Information For patent information, please refer to www.honeywellaidc.com/patents.

Seite 83 - PATENTS

78 INDEX A AC ... see power amber LED ...

Seite 84

79INDEX S safety...74, 75 scale...

Seite 87

December 2006 Printed in the USA 00-02035C

Seite 88 - 00-02035C

3INTRODUCTION OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES Part # Description Optional Remote Scale Display 46-00248 Remote Scale Display for use

Kommentare zu diesen Handbüchern

Keine Kommentare