Metrologic MS7120-38 Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Barcodeleser Metrologic MS7120-38 herunter. Metrologic MS7120-38 User`s guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - METROLOGIC INSTRUMENTS, INC

METROLOGIC INSTRUMENTS, INC.MS7120 Series Fixed Projection Laser ScannerInstallation and User’s GuideMLPN 2408Printed in USADecember 1998

Seite 2 - Locations

6Scanner Installation: Powered by Host DeviceThe MS7120 scanner interfaces terminate to a 10-pin modular jack. Connectthe 10-pin modular plug of the

Seite 3 - Table of Contents

7Scanner Installation to the PC for the Scanner with Built-inPC Keyboard Wedge Interface To maintain compliance with applicable standards, all circuit

Seite 4 - Table of Contents (continued)

8Green and Red LEDs: During normal operation, the greenLED is on. This indicates that the laser is on and the unit isready to scan. On a successful re

Seite 5 - Introduction

9Audible Indicators When the MS7120 scanner is in operation, it provides audible feedback.These sounds indicate the status of t

Seite 6 - Scanner and Accessories

10Failure Modes Flashing Green and One Razzberry ToneThis indicates the scanner has experienced a laser subsystem failure. Retu

Seite 7 - Quick Start

11Visual Indicators There are a red LED and a green LED on the head of the Orbit MS7120.When the sc

Seite 8 - Operational Test

12LabelsEach scanner has labels on the bottom of the unit. One label containsinformation such as the model number, date of manufacture, serial number

Seite 9

13Depth of Field Specifications (based on 100% UPC bar codes)Optimal Low Density Depth of Field (default)Optimal High Density Depth of Field

Seite 10

14Depth of Field Specifications (continued)(based on 100% UPC bar codes)Close Depth of FieldNormal Depth of Field

Seite 11 - PC Keyboard Wedge Interface

15Depth of Field Specifications (continued)(based on 100% UPC bar codes) Far Depth of Field

Seite 12 - ú

iiLocationsUSA Corporate Headquarters EuropeMetrologic Instruments, Inc. Metrologic Instruments GmbH90 Coles Road Dornierstrasse 2Blackwood, NJ 08012

Seite 13 - Three Beeps - on power up

16Depth of Field by Minimum Bar Code Element WidthOptimal Low Density Depth of Field (default)

Seite 14 - Failure Modes

17Depth of Field by Minimum Bar Code Element Width(continued)Optimal High Density Depth of Field (default)

Seite 15

18Depth of Field by Minimum Bar Code Element Width(continued)Close Depth of Field

Seite 16

19Depth of Field by Minimum Bar Code Element Width(continued)Normal Depth of Field

Seite 17 - (based on 100% UPC bar codes)

20Depth of Field by Minimum Bar Code Element Width(continued)Far Depth of Field

Seite 18

21MaintenanceSmudges and dirt can interfere with the proper scanning of a bar code.Therefore, the output window will need occasional cleaning. 1. Spra

Seite 19

22Troubleshooting GuideThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to p

Seite 20

23Troubleshooting Guide (continued)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe unit powers Beeper disabled. No tone Enable beeper. Select toneup, but does

Seite 21 - (continued)

24Troubleshooting Guide (continued)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONScanner beeps at The print quality of the bar Check print mode. The type of prin

Seite 22

25Troubleshooting Guide (continued)Keyboard Wedge OnlySYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe unit scans Configuration is not Make sure the scanner is

Seite 23

iiiTable of ContentsIntroduction ... 1Scanner and Accessories ...

Seite 24

26Troubleshooting Guide (continued)RS-232 onlySYMPTOMS POSSIBLE CAUSE(S) SOLUTIONPower-up OK Com port at the host is not Check to make sure that the b

Seite 25 - Maintenance

27RS-232 Demonstration ProgramIf an RS-232 scanner is not communicating with your IBM compatible PC, key in thefollowing BASIC program to test that

Seite 26 - Troubleshooting Guide

28Applications and ProtocolsThe model number on each scanner includes the scanner number andcommunications protocol.Scanner Version Identifier Communi

Seite 27

29Appendix ADesign SpecificationsOperationalLight Source: VLD 675 ± 5nm, 0.681 milliwatts (PEAK)Depth of Field: 0 mm to 215 mm (0" to 8.5"

Seite 28

30Appendix A (continued)ElectricalInput Voltage: 5.2VDC ± 0.25VPower : 1.1 WOperating Current : 225 mADC Transformers: Class II; 5.2 V @650 mA Laser

Seite 29

31Appendix BDefault SettingsMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from the

Seite 30

Appendix B (continued)32Parameter Default OCIA RS- Light IBM KBW232* Pen 46XXDTS/NIXDORF * TTNCR F TTNCR S TTPoll Light Pen Source TTBeeper Tone Norma

Seite 31 - RS-232 Demonstration Program

Appendix B (continued)33Parameter Default OCIA RS- Light IBM KBW232* Pen 46XXTransmit UPC-A Item ID# * TT TT TT TT TTTransmit Codabar TT TT TT TTSta

Seite 32 - Applications and Protocols

Appendix B (continued)34Parameter Default OCIA RS- Light IBM KBW232* Pen 46XXCharacter RTS/CTS * TTMessage RTS/CTS TTXON/XOFF Handshaking TTACK/NAK T

Seite 33 - Appendix A

Appendix B (continued)35Parameter Default OCIA RS- Light IBM KBW232* Pen 46XXNormal Depth of Field * TT TT TT TT TTExtended Depth of Field TT TT TT TT

Seite 34 - Appendix A (continued)

ivTable of Contents (continued)Appendix ADesign Specifications 29, 30Appendix BDefault Settings 31-35Appendix CPin Assignments 36-38Appendix DWarranty

Seite 35 - Appendix B

36Appendix CPin AssignmentsPin Assignments for the PowerLink CableThe MS7120 scanner interfaces terminate to a 10-pin modular jack. Connect the 10-pin

Seite 36 - Appendix B (continued)

37Appendix C (continued)Pin Assignments for the PowerLink Cable Keyboard WedgeInterface The MS7120 Keyboard Wedge scanner interface terminates to a 10

Seite 37

38 Adapter Cable Connectors 5-pin Male 6-pin Female PowerLink Cable Connectors 5-pin Female 6-pin Male Appen

Seite 38

39Appendix DWarranty and DisclaimerLimited WarrantyProducts manufactured by Metrologic have a 2-year limited warranty fromdate of manufacture.This war

Seite 39

40Appendix D (continued)DisclaimerMetrologic Instruments, Inc. and the author or authors make no claims or warranties with respectto the contents or a

Seite 40 - Appendix C

41Appendix ENoticesNoticeThis equipment has been tested and found to comply with limits for a Class A digital device,pursuant to Part 15 of the FCC Ru

Seite 41 - Appendix C (continued)

42Appendix E (continued)AnmerkungNach Überprüfung dieses Geräts wurde festgestellt, daß es den Grenzwerten für Digitalgeräte derKlasse A gemäß Teil 15

Seite 42

43IndexAAccessories 2AC input/outlet 2, 4, 5, 7Adaptercable 2, 7, 38Approvals 12Assignmentspin 36-38Audible indicators 9Authorized service center 39Au

Seite 43 - Appendix D

44Index (continued)Light Pen 1, 2, 4, 6, 28, 36Light source 29List 2MMaintenance 21Manufacturer’s recommendation7Mechanical 29Min bar width 29NNormal

Seite 44 - Appendix D (continued)

1IntroductionOrbit™ is an aggressive, omnidirectional laser bar code scanner. Light-weightand rugged, Orbit is small in size, but BIG in performance.

Seite 45 - Appendix E

2Scanner and AccessoriesThe following is a list of the parts included in the MS7100 kit.! MS7120 Laser Scanner - Refer to page 28 for available commun

Seite 46 - Appendix E (continued)

3Quick Start 1.) Plug in the scanner. When the MS7120 is ready to scan, the green LED will turn on, then the red LED will flash and the scan

Seite 47

4Operational TestMetrologic recommends using the external power supply provided with thescanner when operating the MS7120. When using power supplied b

Seite 48 - Index (continued)

5Scanner Installation: Powered by External Power SupplyTo maintain compliance with applicable standards, all circuits connected to thescanner must me

Kommentare zu diesen Handbüchern

Keine Kommentare