6 INTRODUCTION Labels Every scanner has labels and molded text located on the underside of the unit. The labels and text contain important inform

Seite 3 - ABLE OF CONTENTS

7INSTALLING THE SCANNER TO THE HOST SYSTEM RS232, OCIA, Laser Emulation, and Light Pen Emulation 1. Turn off the host system. 2. Connect the

Seite 4

8 INSTALLING THE SCANNER TO THE HOST SYSTEM IBM 46XX 1. Turn off the host system. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 1

Seite 5

9INSTALLING THE SCANNER TO THE HOST SYSTEM Keyboard Wedge 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack

Seite 6

10 INSTALLING THE SCANNER TO THE HOST SYSTEM Stand-Alone Keyboard 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into

Seite 7

11Figure 10.INSTALLING THE SCANNER TO THE HOST SYSTEM Integrated USB: Full Speed (-40) Low Speed (-38) 1. Turn off the host system. 2. Co

Seite 8

12 THE MS9540 VOYAGERCG® SERIES How to Use CodeGate and the Manual Activation Mode CODEGATE® MANUAL ACTIVATION MODE* * This feature is not a de

Seite 9

13STAND KITS Types Free Standing Kit #46-46128 (Figure 13) Kit Contains: a. Stand... Q

Seite 10 - INTRODUCTION

14 STAND KITS Assembly There are two options for assembling the stand. The first option is a self-supporting stand that can be moved freely about

Seite 11 - Figure 6

15STAND KITS Assembly Stand Option 2: Hard-Mount Kits #46-46128, #46-46351 and MS951 Stand Replacements Step 3 Screw the stand anchor onto

Seite 12 - IBM 46XX

Copyright © 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, tran

Seite 13 - Keyboard Wedge

16 STAND KITS Assembly Wall Mount, Option 1: For Kit #46-46433 or #46-46508 Step 1 Drill two #39 pilot holes 3.00″ apart. Step 2 Attach the W

Seite 14 - Stand-Alone Keyboard

17INDICATORS Audible When the Voyager is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight s

Seite 15 - Low Speed (-38)

18 INDICATORS Visual The MS9540 has three LED indicators (green, red and yellow) located on the head of the scanner. The MS9520 has two LED indic

Seite 16 - SERIES

19INDICATORS Visual Steady Red, Green* off This indicates the scanner may be waiting for communication from the host. Failure Modes Flashin

Seite 17 - STAND KITS

20 CONFIGURATION MODES The MS9500 Voyager has 3 modes of configuration. • Bar Codes Voyager or Voyager CG can be configured by scanning the bar

Seite 18

21CONFIGURATION MODES 4. During configuration, the motor and laser turn off. YOU CANNOT SCAN A BAR CODE WHILE IN SERIAL CONFIGURATION MODE. 5.

Seite 19

22 CONFIGURATION MODES EXAMPLE #3: The following example shows the events that occur when an invalid bar code is sent. This sample will load the

Seite 20

23UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic’s new line of Flash based scanners. This program

Seite 21 - INDICATORS

24 DEPTH OF FIELD MINIMUM BAR CODE ELEMENT WIDTH A B C D E F G H J K mm .13 .15 - - .19 - .25 .33 .53 - mils 5.2 5.7 - - 7.5 - 10 13 21 -

Seite 22

25IR ACTIVATION RANGE The default laser/scan mode for the MS95x0 series is Normal Scan. Any movement detected by the IR in the activation area w

Seite 23

iiTABLE OF CONTENTS Introduction Product Overview ... 1 S

Seite 24 - CONFIGURATION MODES

26 APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. Scanner V

Seite 25

27TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-38

Seite 26

28 TROUBLESHOOTING GUIDE Symptoms Possible Causes Solution The unit powers up, but does not scan and/or beep. The bar code being scanned does not

Seite 27 - MLPN 54-54012) are required

29TROUBLESHOOTING GUIDE Symptoms Possible Causes Solution The unit scans but the data is not correct. The unit’s configuration is not correct. M

Seite 28 - DEPTH OF FIELD

30 RS232 DEMONSTRATION PROGRAM If an RS232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test tha

Seite 29 - IR ACTIVATION RANGE

31DESIGN SPECIFICATIONS MS9500 Series Specifications OPERATIONAL Light Source Visible Laser Diode 650 nm Laser Power: Less than 1 mW (peak) De

Seite 30 - APPLICATIONS AND PROTOCOLS

32 DESIGN SPECIFICATIONS MS9500 Series Specifications MECHANICAL Length: 198 mm (7.8") Width: Handle - 45 mm (1.8"), Head - 78 mm (3

Seite 31 - TROUBLESHOOTING GUIDE

33DEFAULT SETTINGS Many functions of the scanner can be configured or enabled/disabled. The scanner is shipped from the factory configured to a

Seite 32

34 DEFAULT SETTINGS Parameter Default OCIA RS232Light Pen IBM 46xxKBW USBLaser EmulationMod 43 Check on Code 39        MSI-Pless

Seite 33

35DEFAULT SETTINGS Parameter Default OCIA RS232Light Pen IBM 46xxKBW USBLaser EmulationSame symbol rescan timeout: 750 msecs      

Seite 34 - RS232 DEMONSTRATION PROGRAM

iiiTABLE OF CONTENTS IR Activation Range... 25 Application

Seite 35 - DESIGN SPECIFICATIONS

36 DEFAULT SETTINGS Parameter Default OCIA RS232Light Pen IBM 46xxKBW USBLaser EmulationTransmit Sanyo ID Characters   Nixdorf ID 

Seite 36

37DEFAULT SETTINGS Parameter Default OCIA RS232Light Pen IBM 46xxKBW USBLaser Emulation100 msec to Find Supplement Configurable in 100 msec st

Seite 37 - DEFAULT SETTINGS

38 110SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections MS95x0-41 RS232 and Light Pen Emulation Pin Function 1 Ground 2 RS232 Transmit O

Seite 38

39110SCANNER AND CABLE TERMINATIONS MS95x0-9 OCIA Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RDATA 5 RDATA Return

Seite 39

40 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) RS232 PowerLink Cable MLPN 53-53000x-3 Pin Function 1 Shield Ground

Seite 40

41SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) USB Cables MLPN 53-53213x-N-3, 53-53214x-N-3 or 53-53235x-N-3 Pin F

Seite 41

42 SCANNER AND CABLE TERMINATIONS Cable Connector Configuration (Host End) Keyboard Wedge PowerLink Cable MLPN 53-53002x-3 Pin Function 1 Keybo

Seite 42 - Scanner Pinout Connections

43LIMITED WARRANTY The MS9500 Voyager and VoyagerCG series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility.

Seite 43

44 REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Cau

Seite 44 - MLPN 53-53015x-3

45REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Changes or modifications not expr

Seite 45 - 6-Pin Male Mini-DIN Connector

1INTRODUCTION Product Overview Metrologic’s MS9520 Voyager® and the MS9540 VoyagerCG® are a group of single-line laser bar code scanners that ha

Seite 46 - MLPN 53-53002x-3

46 REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s author

Seite 47 - LIMITED WARRANTY

47PATENTS This METROLOGIC product may be covered by, but not limited to, one or more of the following US Patents: US Patent No. 4,958,984; 5,081

Seite 48 - REGULATORY COMPLIANCE

48 INDEX A AC ... see power accessories ...3, 4 adapter ...

Seite 49

49INDEX O OCIA ... see interface output window ...5 P parameter...38–

Seite 52

February 2007 Printed in the USA 00-02410J

Seite 53

2 INTRODUCTION Scanner and Accessories BASIC KIT Part # Description MS9520 or MS9540 Voyager or VoyagerCG Bar Code Scanner 00-02544 MetroSelect

Seite 54

3INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part # Description 53-53015x-3 OCIA PowerLink Cable with Built in Power Jack 2.7 m (9

Seite 55

4 INTRODUCTION Scanner Components No. Item Description 1 Green LED* See Visual Indicators on page 18 2 Red LED* See Visual Indicators on page

Seite 56 - Printed in the USA

5INTRODUCTION Disconnecting the PowerLink Cable Before removing the cable from the scanner, Metrologic recommends that the power on the host sy

Kommentare zu diesen Handbüchern

Keine Kommentare