Seite 1 - Installation and User’s Guide

METROLOGIC INSTRUMENTS, INC.MS9500 Voyager® SeriesSingle-Line Hand-Held Laser ScannerInstallation and User’s Guide

Seite 2

4OPERATIONAL TEST1. Connect the 10-pin RJ45 maleconnector into the jack on theVoyager or VoyagerCG. Youwill hear a ‘click’ when theconnection is mad

Seite 3 - LOCATIONS

5INSTALLING THE SCANNER TO THE HOST SYSTEMMS9520-00/9/11/14/41 AND MS9540-00/9/11/14/411. Turn off the host system.2. Connect the 10-pin RJ45 maleco

Seite 4 - TABLE OF CONTENTS

6INSTALLING THE SCANNER TO THE HOST SYSTEMKEYBOARD WEDGE MS9520-47 AND MS9540-471. Turn off the PC.2. Connect the 10-pin RJ45 maleconnector into the

Seite 5

7INSTALLING THE SCANNER TO THE HOST SYSTEMSTAND ALONE KEYBOARD1. Turn off the host system.2. Connect the 10-pin RJ45 maleconnector into the jack on

Seite 6

8Figure 7.INSTALLING THE SCANNER TO THE HOST SYSTEMINTEGRATED USB: FULL SPEED MS9520-40 AND MS9540-40LOW SPEED POS MS9520-39 AND MS9540-39LOW SPEED HI

Seite 7 - INTRODUCTION

9THE POWERLINK CABLEDISCONNECTING THE POWERLINK CABLEBefore removing the cable from the scanner, Metrologic recommends that thepower on the host syste

Seite 8 - SCANNER AND ACCESSORIES

10THE MS9540 VOYAGERCG® SERIESHOW TO USE CODEGATE AND THE MANUAL ACTIVATION MODECODEGATE®MANUAL ACTIVATION MODE** This feature is not a default settin

Seite 9

11STAND KITSFree Standing Kits #46-46128Contains:a. Stand (MLPN 36-00454)...Qty 1b. Apron (MLPN 50-50440) ...

Seite 10 - OPERATIONAL TEST

12ASSEMBLING THE STANDThere are two options for assembling the stand. The first option is a self-supporting stand that can be moved freely about on t

Seite 11 - Figure 4

13ASSEMBLING THE STANDStand Option 2: Hard-Mount Kits #46-46128, #46-46351 andMS951 Stand ReplacementsStep 3Screw the stand anchor (MLPN 50-50449)ont

Seite 13 - STAND ALONE KEYBOARD

14ASSEMBLING THE STANDWall Mount, Option 1:For Kit #46-46433 or #46-46508Step 1Drill two #39 pilot holes 3.00” apart.Step 2Attach the Wall Mount Hange

Seite 14 - Figure 7

15SCANNER PARTSFigure 29.MS9500 Top ViewMS9500 Side ViewYellow LED*CodeGate Button*Output WindowCable ConnectionRed LEDGreen LED* This feature is not

Seite 15 - THE POWERLINK CABLE

16AUDIBLE INDICATORSWhen the Voyager is in operation, it provides audible feedback. These soundsindicate the status of the scanner. Eight settings a

Seite 16 - THE MS9540 VOYAGERCG

17VISUAL INDICATORSThe MS9540 has three LED indicators (green, red and yellow) located on thehead of the scanner. The MS9520 has two LED indicators (

Seite 17 - STAND KITS

18FAILURE MODESFlashing Green and one Razzberry ToneThis indicates the scanner has experienced a laser sub-system failure. Return the unit for repair

Seite 18 - ASSEMBLING THE STAND

19PROGRAMMING MODESThe MS9500 Voyager has 3 modes of programming.¾ Bar CodesVoyager or Voyager CG can be configured by scanning the bar codeslocated

Seite 19

20PROGRAMMING MODES4. During programming, the motor and laser turn off. YOU CANNOT SCAN ABAR CODE WHILE IN SERIAL PROGRAM MODE.5. There is a 20 sec

Seite 20

21PROGRAMMING MODESEXAMPLE #3:The following example shows the events that occur when an invalid bar codeis sent. This sample will load the factory de

Seite 21 - SCANNER PARTS

22UPGRADING THE FLASH ROM FIRMWAREThe MetroSet2 program is a functional component of Metrologic’s new line ofFlash- based scanners. This program allo

Seite 22 - AUDIBLE INDICATORS

23LABELSEach scanner has a label on the back of the unit. This label has the modelnumber, date of manufacture, serial number, CE and caution informat

Seite 23 - VISUAL INDICATORS

iiLOCATIONSCORPORATE HEADQUARTERSNORTH AMERICAEUROPEAN, MIDDLE EAST & AFRICANHEADQUARTERSUSA, NEW JERSEY GERMANY, MUNICHMetrologic Instruments, In

Seite 24 - FAILURE MODES

24DEPTH OF FIELDMinimum Bar Code Element WidthABCDEFGHJKmm.13 .15 - - .19 - .25 .33 .53 -mils5.2 5.7 - - 7.5 - 10 13 21 -Figure 31.

Seite 25 - ¾ Serial Programming

25IR ACTIVATIONFigure 32.

Seite 26 - PROGRAMMING MODES

26APPLICATIONS AND PROTOCOLSThe model number on each scanner includes the scanner number and factorydefault communications protocol.Scanner Version Id

Seite 27

27TROUBLESHOOTING GUIDEThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-Metro or 1-800-436-3876 to

Seite 28 - MLPN 54-54012) are required

28TROUBLESHOOTING GUIDESymptoms Possible Causes SolutionThe unit powersup, but does notbeep.The beeper may bedisabled or no tonehas been selected.Enab

Seite 29 - MAINTENANCE

29TROUBLESHOOTING GUIDESymptoms Possible Causes SolutionThe bar code mayhave been printedincorrectly.The unit beepsat some barcodes but NOTfor others

Seite 30 - DEPTH OF FIELD

30TROUBLESHOOTING GUIDESymptoms Possible Causes SolutionAlphacharacters showas lower case.The computer is inCaps Lock mode.Enable the Caps Lock detect

Seite 31 - IR ACTIVATION

31RS-232 DEMONSTRATION PROGRAMIf an RS-232 scanner is not communicating with your IBM compatible PC, key inthe following BASIC program to test that th

Seite 32 - APPLICATIONS AND PROTOCOLS

32DESIGN SPECIFICATIONSOPERATIONALLight Source Visible Laser Diode 650 nm ± 10 nmLaser Power: Less than 1 mW (peak)Depth of Scan Field:0 mm - 203 mm (

Seite 33 - TROUBLESHOOTING GUIDE

33DESIGN SPECIFICATIONSELECTRICALInput Voltage: 5VDC ± 0.25VPower: Operating = 0.825 W, Standby = 0.600 WCurrent:Operating = 165 mA @ 5VDC,Standby =

Seite 34

iiiTABLE OF CONTENTSIntroduction... 1Scanner a

Seite 35

34DEFAULT SETTINGSMany functions of the scanner can be “configured” or enabled/disabled. Thescanner is shipped from the factory configured to a set o

Seite 36

35DEFAULT SETTINGSPARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XXKBW USBLASEREMULATIONMod 43 Check on Code 3999 9999 9MSI-Plessy 10/10Check Digit99 9999

Seite 37 - RS-232 DEMONSTRATION PROGRAM

36DEFAULT SETTINGSPARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XXKBW USBLASEREMULATIONSame symbol rescan timeout:750 msecs99 9999 9Same symbol rescan tim

Seite 38 - DESIGN SPECIFICATIONS

37DEFAULT SETTINGSPARAMETER DEFAULT OCIA RS-232LIGH TPENIBM46XXKBW USBLASEREMU LATIONTransmit Sanyo IDCharacters99Nixdorf ID 99LRC Enabled 99UPC Prefi

Seite 39

38DEFAULT SETTINGSPARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XXKBW USBLASEREMULATION100 msec to Find SupplementProgrammable in 100 msecsteps(max 800 ms

Seite 40 - DEFAULT SETTINGS

39110SCANNER AND CABLE TERMINATIONSScanner Pinout ConnectionsMS9520/40-41RS-232C and Light Pen EmulationPin Function1 Ground2 RS-232 Transmit Output3

Seite 41

40110SCANNER AND CABLE TERMINATIONSMS9520/40-9 OCIAPin Function1 Ground2 RS232 Transmit Output3 RS232 Receive Input4 RDATA5 RDATA Return6 Clock In7Clo

Seite 42

41SCANNER AND CABLE TERMINATIONSCable Connector Configurations (Host End)“Standard” PowerLink Cable53-53xxx coiled or 54-54xxx straightPin Function1 S

Seite 43

42SCANNER AND CABLE TERMINATIONSCable Connector Configuration (Host End)Keyboard Wedge PowerLink Cable53-53002 or 54-54002Pin Function1 Keyboard Clock

Seite 44

43LIMITED WARRANTYThe MS9500 series scanners are manufactured by Metrologic at its Blackwood, NewJersey, USA facility. The MS9500 series scanners have

Seite 45 - CANNER AND CABLE TERMINATIONS

ivTABLE OF CONTENTSIR Activation ... 25Application

Seite 46

44NOTICESNoticeThis equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the FCC rules. T

Seite 47

45PATENTS“Patent InformationThis METROLOGIC product may be covered by one or more of the following USPatents:US Patent No. 4,958,984; 5,081,342; 5,260

Seite 48

46INDEXAAC Input/Outlet...5, 6, 7Accessories...2Adapter...2A

Seite 49 - LIMITED WARRANTY

47INDEXMMaintenance...23Meteor ...22MVC ...

Seite 52

October 2003Printed in the USA 00- 02410D

Seite 54

1INTRODUCTIONThe Voyager® MS9500 Series single-line hand-held scanners include both theMS9520 and MS9540.The VoyagerCG® MS9540 features Metrologic’s p

Seite 55

2SCANNER AND ACCESSORIESBASIC KITPart # DescriptionMS9500 Voyager Series Scanner00-02544 MetroSelect Single-Line Programming Guide*00-02410MS9500 Voya

Seite 56 - Printed in the USA

3SCANNER AND ACCESSORIESOPTIONAL ACCESSORIESPart # Description53-53213USB Power/Communication Cable,3 m (10’) coiled cord, long strain relief, gray53-