Inhaltsverzeichnis

Seite 1 - Scanner / Diva Scale

METROLOGIC INSTRUMENTS, INC. MS2220 StratosS™ Scanner / Diva Scale Installation and User’s Guide

Seite 2

4 INTRODUCTION REPLACEMENT PARTS REPLACEMENT PARTS Part # Description Caution Window types (Diamonex and Sapphire) are not interchangeable due

Seite 3 - ABLE OF CONTENTS

5INTRODUCTION GENERAL PRECAUTIONS The following are some general precautions to remember when handling your MS2200 Series scanner. DO NOT TU

Seite 4

6 INTRODUCTION MS2200 SERIES DESIGN SPECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <1.5 mW M

Seite 5

7BASE MODEL CHARACTERISTICS MS2220 Scanner/Mettler Toledo DIVA Scale Components Figure 7. MS2220 Components

Seite 6

8 BASE MODEL CHARACTERISTICS MS2220 Scanner/Mettler Toledo DIVA Scale Components ITEM NO. DESCRIPTION OF ITEM IN FIGURE 7 1 Scale Zero Butto

Seite 7

9BASE MODEL CHARACTERISTICS MS2220 Scanner/Diva Scale Dimensions Figure 8. MS2220 Dimensions Specifications are subject to change without not

Seite 8

10 BASE MODEL CHARACTERISTICS MS2220 Scanner/Diva Scale Caution and Serial Number Labels Figure 10. MS2220 Label Locations (Top) and Examples

Seite 9

11 INSTALLATION QUICK INSTALLATION OUTLINE The following is a quick preview of the steps required for 1st time installations. Each item is disc

Seite 10 - INTRODUCTION

12 INSTALLATION SITE REQUIREMENTS Power Installation The Power Supply (AC/DC) should be connected to an AC Outlet that is free of electrical n

Seite 11

13INSTALLATION UNPACKING THE UNIT 1. Make sure the shipping box is top-side up before opening. 2. Remove the accessories box and check the

Seite 12

Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work ma

Seite 13 - BASE MODEL CHARACTERISTICS

14 INSTALLATION UNPACKING THE UNIT MS2220 Package Warning There is a protective film located on the topside platter surface, vertical scan windo

Seite 14

15INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2220 Mounting Diagram Figure 17. MS2220 Mounting Diagram Specifications are subject to c

Seite 15

16 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 The following steps describe how to properly install the cables for an RS232 Stra

Seite 16

17INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 9. Turn on the host system. 10. Scan the recall Recall Defaults bar code. The

Seite 17 - INSTALLATION

18 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB The following steps describe how to properly install the cables for a Full

Seite 18

19INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB 9. Turn on the host system. 10. Configure the StratosS to match the host

Seite 19

20 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB xx** Specifies international connection. See the Base Kit Component

Seite 20

21INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) IBM 46XX The following steps describe how to properly install the cables for an IBM 46xx

Seite 21

22 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) IBM 46XX 9. Turn on the host system. 10. Configure the StratosS to match the host syst

Seite 22

23INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) OCIA The following steps describe how to properly install the cables for an OCIA StratosS

Seite 23

iiTABLE OF CONTENTS INTRODUCTION Manual Scope ...

Seite 24

24 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) OCIA 8. Connect AC power to the transformer. If the AC outlet is equipped with an on/of

Seite 25 - NSTALLATION

25INSTALLATION CABLE INSTALLATION (SECONDARY METROLOGIC SCANNER) The following steps describe how to properly install the cables between a seconda

Seite 26

26 INSTALLATION CABLE INSTALLATION (SECONDARY METROLOGIC SCANNER) † See Aux power notes on page 25 See power source caution statement on pa

Seite 27

27INSTALLATION EAS DEACTIVATION SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. The following is a

Seite 28

28 SCANNER OPERATION SCAN ZONE Figure 25. Checker-Side (13 mil) Figure 26. Horizontal Left/Right (13 mil) Specifications are subject

Seite 29

29SCANNER OPERATION SCAN ZONE Figure 27. Horizontal Direct (13 mil) Figure 28. Vertical Direct (13 mil) Specifications are subject to c

Seite 30

30 SCANNER OPERATION IR ACTIVATION AREA (IR LED OUTPUT) The StratosS’s default power save mode† is Dual Action Power Save Mode #2 (see page 36).

Seite 31

31SCANNER OPERATION INDICATOR DESCRIPTIONS Audible When in operation the StratosS provides audible feedback that indicates the status of the un

Seite 32

32 SCANNER OPERATION INDICATOR DESCRIPTIONS Visual (Continued) Steady Blue and Single White Flash When the scanner successfully reads a bar co

Seite 33

33SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display There is a two-digit error code display located under horizontal output

Seite 34 - SCANNER OPERATION

iiiTABLE OF CONTENTS SCANNER OPERATION Scan Zone...

Seite 35

34 SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE DESCRIPTION 13 SCALE ERROR The scanner does not communicate

Seite 36

35SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE DESCRIPTION 27 Laser #1 (Vertical) Undercurrent Warning – The

Seite 37 - INDICATOR DESCRIPTIONS

36 SCANNER OPERATION POWER SAVE MODES The MS2220 has five configurable power save modes. Refer to the MetroSelect Configuration Guide for additi

Seite 38

37SCANNER OPERATION BEEPER OPTIONS AND BUTTON FUNCTIONS Changing the Beeper Tone Beeper tones may be configured incrementally using the following

Seite 39

38 SCANNER OPERATION STARTUP When the scanner first receives power the white LED will flash, the blue LED will turn on and the scanner will beep

Seite 40

39SCALE OPERATION SCALE ZEROING After the unit has been officially calibrated (see page 40) the scale can be re-zeroed by pressing the scale zero

Seite 41

40 SCALE OPERATION CALIBRATION The scanner/Diva scale must be calibrated if:  it is a first time installation  the scale cannot be re-zeroed

Seite 42

41SCALE OPERATION CALIBRATION Priming the Scale for Calibration (lbs. or kg) Prime the scale before starting either method of calibration. Cal

Seite 43

42 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display* 1. Temporarily remove the platter and place it in

Seite 44

43SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display* 4. Reinstall the platter onto the scanner/Diva sca

Seite 45 - SCALE OPERATION

ivTABLE OF CONTENTS SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections...

Seite 46

44 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display 7. Go to Group 2 Step 6 (Calibration) of the Service

Seite 47

45SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* The following calibration procedure can be used when the

Seite 48

46 ³996042SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* 4. Reinstall the platter onto the scanner/Diva sca

Seite 49

47³996044SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* Unit Calibration (Kilograms) For Pound weight units

Seite 50 - CALIBRATION

48 SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* 6. Make sure there is no load on the scale platter. The

Seite 51

49SCALE OPERATION CALIBRATION VERIFICATION U.S. Pounds (lbs.) The following tests verify if the scale's Calibration is accurate. For Kilog

Seite 52

50 SCALE OPERATION CALIBRATION VERIFICATION Kilograms (kg) The following tests verify if the scale's Calibration is accurate. For US Pou

Seite 53

51SCALE OPERATION SECURITY SEAL INSTALLATION The certification of the weighing mechanism of the scale version of this scanner is subject to fede

Seite 54

52 SCALE OPERATION SECURITY SEAL INSTALLATION Wire Security Seal (Seal Conversion Kit MLPN 46-00359)* 1. Temporarily remove the platter and p

Seite 55

53MAINTENANCE HORIZONTAL SCAN WINDOW REPLACEMENT Figure 61. Platter/Horizontal Scan Window Replacement * See replacement parts on page 4.

Seite 57

54 MAINTENANCE VERTICAL SCAN WINDOW REPLACEMENT (MLPN 46-00232) Figure 62. Vertical Scan Window Replacement DAILY MAINTENANCE Smudges and d

Seite 58

55TROUBLESHOOTING The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to

Seite 59 - MAINTENANCE

56 TROUBLESHOOTING Symptom Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan (the white LED

Seite 60

57TROUBLESHOOTING Symptom Possible Cause(s) Solution RS232 Only The com port at the host is not working or is not configured properly. The cable

Seite 61 - TROUBLESHOOTING

58 TROUBLESHOOTING RS232 DEMONSTRATION PROGRAM If an RS232 scanner is not communicating with your IBM compatible PC, key in the following BASIC

Seite 62

59DEFAULT SETTINGS COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is, enabled or disabled. The sca

Seite 63

60 DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB RSS Expanded Enable 9 9 9 9 Expanded ID “]e0” * 9

Seite 64

61DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Dual Action Power Save Mode #1 9 9 9 9 Dual Action

Seite 65 - DEFAULT SETTINGS

62 DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Transmit UK Plessey Check Digit 9 9 9 9 EAN 128 E

Seite 66

63DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Recv “i” = Transmit Scanner ID Byte 9 STX Prefix

Seite 67

1INTRODUCTION MANUAL SCOPE This guide provides information on the installation, setup and operation of Metrologic’s StratosS, MS2220 scanner/Div

Seite 68

64 DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Two Digit Redundancy 9 9 9 9 Five Digit Redundanc

Seite 69

65DEFAULT SETTINGS COMMUNICATION PARAMETERS Default settings for “Aux” interface The secondary scanner and the MS2220 series always communicates

Seite 70

66 SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS The MS2220 Series scanner interfaces terminate to 10-pin modular jacks located on t

Seite 71

67SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS Figure 64. Scale Connector Layout Scale RS232 to Host Scale Data, Dual Cable

Seite 72 - SCANNER PINOUT CONNECTIONS

68 SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS RS232 Interface Cable, MLPN 57-57210x-N-3 Pin Function ** 1 No Connect 2 RS23

Seite 73

69SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS Aux Port Configuration Cable*, MLPN 57-57008x-N-3 Pin Function** 1 No Connect

Seite 74 - MLPN 57-57016x-N-3

70 REGULATORY COMPLIANCE SAFETY ITE Equipment IEC 60950-1; EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN: 60825-1:1994+A1+A2 Ca

Seite 75 - 10-Position Modular Plug

71REGULATORY COMPLIANCE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Class A Devices The following

Seite 76 - REGULATORY COMPLIANCE

72 REGULATORY COMPLIANCE EMC Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when

Seite 77

73LIMITED WARRANTY The MS2220 StratosS™ Series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS2200

Seite 78

2 INTRODUCTION BASE KIT COMPONENTS BASE KIT COMPONENTS Part # Description MS2220-105Kz StratosS™ Scanner/Diva Scale D Diamonex Horizontal Wind

Seite 79 - LIMITED WARRANTY

74 PATENTS For patent information, please refer to www.honeywellaidc.com/patents.

Seite 80 - PATENTS

75INDEX A AC ... see power amber LED ...

Seite 81

76 INDEX R razzberry tone ...31, 32, 60 regulatory compliance ...

Seite 85

December 2006 (Version 1) Printed in the USA 00-02274A

Seite 86 - 00-02274A

3INTRODUCTION OPTIONAL ACCESSORIES AC to DC Power Transformer - Regulated Output: +5.2V @ 2A +12V @ 1A Part # Description 46-00226 120V U

Kommentare zu diesen Handbüchern