Code Bytes
M
1
SECTION M CODE BYTE USAGE
User configurable prefixes, symbol length and other features that use these code bytes
for configuration, require that the scanner be in configuration mode. Scan the Enter/Exit
Configuration Mode bar code before starting the configuration cycle. Single code
configuration mode does not work for these multi-code sequences.
Enter/Exit Configuration Mode
³999999
EXAMPLE
User configurable prefix/suffix characters (Section E) can be saved into the
scanner by scanning the 3 digit decimal equivalent of the ASCII character into
the appropriate character location with the code byte bar codes.
To add an asterisk (*) as a prefix scan the following bar codes in order:
1. Enter/Exit Configuration Mode (3 beeps)
2. Configurable Prefix 1 (1 beep)
3. Code Byte 0 (1 beep)
4. Code Byte 4 (2 beeps)
5. Code Byte 2 (3 beeps)
6. Enter/Exit Configuration Mode (3 beeps)