Scanner Operation
D
4
SECTION D REDUNDANT SCANS
* 0 Redundant Scans 1 Redundant Scans
³301100
Requires 1 good decode for
a “good scan”.
³301110
Requires 2 consecutive
decodes of the same bar
code data for a “good scan”.
2 Redundant Scans 3 Redundant Scans
³301120
Requires 3 consecutive
decodes of the same bar
code data for a “good scan”.
³301130
Requires 4 consecutive
decodes of the same bar
code data for a “good scan”.