METROLOGIC INSTRUMENTS, INC. MS7320 InVista® Series Installation and User’s Guide
6 INSTALLATION FOR STAND-ALONE KEYBOARD INTERFACE 1. Turn off the host system. 2. Disconnect the keyboard from the host. 3. Connect the Power
7INSTALLATION FOR USB INTERFACE 1. Turn off the host system. 2. Determine if your application requires USB Keyboard communication protocols or
8 INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES 1. Turn off the host system. 2. Connect the PowerLink cable to the 10-pin RS232/Light Pen inte
9INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES Codes needed for Step 7 on page 8. For RS232 Communication: Scan 1st ³999998Recall Defaults
10 INSTALLATION FOR IBM 46XX INTERFACE 1. Turn off the host system. 2. Connect the MVC cable to the 10-pin IBM 46xx interface jack. It is the
11INSTALLATION OF A SECONDARY SCANNER 1. Turn off the host system. 2. Connect the round end of the PowerLink RS232 AUX cable [ MLPN 54-54667 ]
12 INSTALLATION OF A SECONDARY SCANNER 11. Scan the following bar code to configure the auxiliary port on the MS7320 to accept a Metrologic scanne
13INSTALLATION OF A SECONDARY SCANNER Figure 7: Connector Orientation (Top) Auxiliary Scanner Setup (Bottom)
14 SCANNER PARTS Figure 8: Scanner Parts Output Window (Laser Aperture) Speaker Replaceable Window Face Plate Red LED (Top LED)
15CABLE COVER INSTALLATION AND REMOVAL FACE PLATE REMOVAL Figure 10: Face Plate Removal Figure 9: Installing the Cable Cover (left). Remo
Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, tra
16 SCANNER LABELS The MS7320 has 2 labels on the back of the unit. These labels contain the model number, date of manufacture, serial number, and
17AUDIBLE INDICATORS When the MS7320 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eigh
18 VISUAL INDICATORS There is a red LED and green LED on the front of the MS7320. When the scanner is on, the flashing or constant illumination o
19FAILURE MODES Figure 13: LEDs Flashing Green and One Razzberry Tone This indicates the scanner has experienced a laser subsystem failure.
20 POWER SAVE MODES AND THE MULTI-FUNCTION BUTTON The MS7320 has five configurable power save modes. Refer to the MetroSelect Configuration Guide
21POWER SAVE MODES AND THE MULTI-FUNCTION BUTTON Figure 14: The Multi-Function Button CHANGING THE BEEPER TONE A Short (<3 second) depressio
22 SCAN VOLUME (BASED ON 100% UPC BAR CODES) Figure 18: Scan Area Top View (top) Side View (Bottom) Specifications are subject to change with
23DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH (BASED ON 100% UPC BAR CODES) Figure 19: Depth of Field Top View Minimum Bar Code El
24 DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH (BASED ON 100% UPC BAR CODES) Figure 20: Depth of Field Side View Minimum Bar Code Ele
25FLEX STAND INSTALLATION Flex Stand (Optional), Kit Components a. Stand Base Cover...Qty. 1 b. Stand Base ...
iiTABLE OF CONTENTS Introduction... 1 Scann
26 FLEX STAND INSTALLATION 2. Secure the base plate to the counter and attach the flex pole assembly. Slide the flex cover(s)* over the flex pole
27 FLEX STAND INSTALLATION 5. Attach the scanner pedestal to the flex pole. Figure 27: Attach Pedestal to Pole 6. Slide the scanner onto the p
28 EAS DEACTIVATION ANTENNA SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. Metrologic recommends
29TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-387
30 TROUBLESHOOTING GUIDE SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Scanning a particular symbology that is not enabled. UPC/EAN, Code 39, interleaved 2
31TROUBLESHOOTING GUIDE SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The bar code may have been printed incorrectly. Check if it is a check digit/character
32 TROUBLESHOOTING GUIDE SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Everything works except for a couple of characters. These characters may not be suppo
33TROUBLESHOOTING GUIDE SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The host is receiving data but the data does not look correct. The scanner and host ma
34 DESIGN SPECIFICATIONS MS7320 SERIES DESIGN SPECIFICATIONS OPERATIONAL Light Source: Visible Laser Diode (VLD) @ 650 nm Laser Power: 0.678 mW
35DESIGN SPECIFICATIONS MS7320 SERIES DESIGN SPECIFICATIONS ELECTRICAL Input Voltage: 5.2VDC ± 0.25V Power: 1.9 W Operating Current: 360 mA DC
iiiTABLE OF CONTENTS Default Settings ... 40 Scanner
36 RS232 DEMONSTRATION PROGRAM If an RS232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test t
37APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER VER
38 CONFIGURATION MODES The MS7320 has three modes of configuration. • Bar Codes The MS7320 can be configured by scanning the bar codes included
39UPGRADING THE FIRMWARE The MS7320 is part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires, a
40 DEFAULT SETTINGS Many functions of the scanner can be "configured" - that is, enabled or disabled. The scanner is shipped from the fac
41DEFAULT SETTINGS PARAMETER DEFAULT OCIA RS232 LIGHT PEN IBM 46XX KBW USB Spaces High as Code 39 Bars High as Scanned Space
42 DEFAULT SETTINGS PARAMETER DEFAULT OCIA RS232 LIGHT PEN IBM 46XX KBW USB Same Symbol Rescan Timeout: 2000 msecs Intercharac
43DEFAULT SETTINGS PARAMETER DEFAULT OCIA RS232 LIGHT PEN IBM 46XXKBW USB 8 Data Bits 7 Data Bits * Transmit Sanyo ID Chara
44 DEFAULT SETTINGS PARAMETER DEFAULT OCIA RS232 LIGHT PEN IBM 46XX KBW USB Bookland 977 (2 digit) Supplemental Requirement S
45DEFAULT SETTINGS Default settings for “Aux” interface The secondary scanner and the MS7320 always communicate via RS232. Data is relayed to the
1INTRODUCTION The MS7320 InVista® offers an outstanding combination of features, versatility, performance, and durability. This fixed mount laser
46 SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS7320 scanner interfaces terminate to 10-pin modular jacks located on the bac
47SCANNER AND CABLE TERMINATIONS Figure 32: Scanner Interface Ports MS732x-37 Keyboard Wedge, Stand-Alone Keyboard or USB MS732x-37 RS232 or
48 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) PowerLink Cable MLPN 59-59xxx* Pin Function 1 Shield Ground 2 RS232
49SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) PowerLink, Keyboard Wedge MLPN 59-59002 Pin Function 1 Key board Cloc
50 LIMITED WARRANTY The MS7320 InVista® Series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS7320
51REGULATORY COMPLIANCE SAFETY ITE Equipment IEC 60950-1; EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN: 60825-1:1994+A1+A2 Cau
52 REGULATORY COMPLIANCE SAFETY Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gef
53REGULATORY COMPLIANCE EMC Class A Devices (Continued…) This device complies with part 15 of the FCC Rules. Operation is subject to the followi
54 REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s autho
55PATENTS For patent information, please refer to www.honeywellaidc.com/patents.
2 SCANNER AND ACCESSORIES BASIC KIT Part # Description MS7320 InVista Series Scanner 00-02407 MetroSelect® Configuration Guide 00-02896 MS7320 I
56 INDEX A Accessories ...2 Adapter...49 Auxiliary...2, 33, 45,
57INDEX M Maintenance...14 Manual...2, 37 MetroSelect ...
January 2008 Printed in the USA 00 - 02896G
3SCANNER AND ACCESSORIES OPTIONAL ACCESSORIES Part # Description AC to DC Power Transformer - Regulated 5.2V@ 1A output 46-46759 120V United Stat
4 INSTALLATION FOR OCIA INTERFACE 1. Turn off the host system. 2. Connect the MVC cable to the 10-pin OCIA interface jack. It is the 2nd round
5Figure 2: Keyboard Wedge InterfacesINSTALLATION FOR KEYBOARD WEDGE INTERFACE 1. Turn off the host system. 2. Disconnect the keyboard from the
Kommentare zu diesen Handbüchern