Metrologic MS7320 Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Barcodeleser Metrologic MS7320 herunter. Metrologic MS7320 User`s guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Series

METROLOGIC INSTRUMENTS, INC. MS7320 InVista® Series Installation and User’s Guide

Seite 2

6 INSTALLATION FOR STAND-ALONE KEYBOARD INTERFACE 1. Turn off the host system. 2. Disconnect the keyboard from the host. 3. Connect the Power

Seite 3 - ABLE OF CONTENTS

7INSTALLATION FOR USB INTERFACE 1. Turn off the host system. 2. Determine if your application requires USB Keyboard communication protocols or

Seite 4

8 INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES 1. Turn off the host system. 2. Connect the PowerLink cable to the 10-pin RS232/Light Pen inte

Seite 5 - INTRODUCTION

9INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES Codes needed for Step 7 on page 8. For RS232 Communication: Scan 1st ³999998Recall Defaults

Seite 6 - SCANNER AND ACCESSORIES

10 INSTALLATION FOR IBM 46XX INTERFACE 1. Turn off the host system. 2. Connect the MVC cable to the 10-pin IBM 46xx interface jack. It is the

Seite 7

11INSTALLATION OF A SECONDARY SCANNER 1. Turn off the host system. 2. Connect the round end of the PowerLink RS232 AUX cable [ MLPN 54-54667 ]

Seite 8 - Load OCIA Defaults

12 INSTALLATION OF A SECONDARY SCANNER 11. Scan the following bar code to configure the auxiliary port on the MS7320 to accept a Metrologic scanne

Seite 9 - Wedge Defaults

13INSTALLATION OF A SECONDARY SCANNER Figure 7: Connector Orientation (Top) Auxiliary Scanner Setup (Bottom)

Seite 10 - ³5155153

14 SCANNER PARTS Figure 8: Scanner Parts  Output Window (Laser Aperture)  Speaker  Replaceable Window Face Plate  Red LED (Top LED)

Seite 11 - Enable USB Defaults

15CABLE COVER INSTALLATION AND REMOVAL FACE PLATE REMOVAL Figure 10: Face Plate Removal Figure 9: Installing the Cable Cover (left). Remo

Seite 12

Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, tra

Seite 13 - Recall Defaults

16 SCANNER LABELS The MS7320 has 2 labels on the back of the unit. These labels contain the model number, date of manufacture, serial number, and

Seite 14 - Load 46xx IBM Defaults

17AUDIBLE INDICATORS When the MS7320 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eigh

Seite 15

18 VISUAL INDICATORS There is a red LED and green LED on the front of the MS7320. When the scanner is on, the flashing or constant illumination o

Seite 16 - Enable Aux Port

19FAILURE MODES Figure 13: LEDs Flashing Green and One Razzberry Tone This indicates the scanner has experienced a laser subsystem failure.

Seite 17

20 POWER SAVE MODES AND THE MULTI-FUNCTION BUTTON The MS7320 has five configurable power save modes. Refer to the MetroSelect Configuration Guide

Seite 18 - AINTENANCE

21POWER SAVE MODES AND THE MULTI-FUNCTION BUTTON Figure 14: The Multi-Function Button CHANGING THE BEEPER TONE A Short (<3 second) depressio

Seite 19 - FACE PLATE REMOVAL

22 SCAN VOLUME (BASED ON 100% UPC BAR CODES) Figure 18: Scan Area Top View (top) Side View (Bottom) Specifications are subject to change with

Seite 20 - SCANNER LABELS

23DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH (BASED ON 100% UPC BAR CODES) Figure 19: Depth of Field Top View Minimum Bar Code El

Seite 21 - AUDIBLE INDICATORS

24 DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH (BASED ON 100% UPC BAR CODES) Figure 20: Depth of Field Side View Minimum Bar Code Ele

Seite 22 - VISUAL INDICATORS

25FLEX STAND INSTALLATION Flex Stand (Optional), Kit Components a. Stand Base Cover...Qty. 1 b. Stand Base ...

Seite 23 - FAILURE MODES

iiTABLE OF CONTENTS Introduction... 1 Scann

Seite 24

26 FLEX STAND INSTALLATION 2. Secure the base plate to the counter and attach the flex pole assembly. Slide the flex cover(s)* over the flex pole

Seite 25 - OWER SAVE MODE

27 FLEX STAND INSTALLATION 5. Attach the scanner pedestal to the flex pole. Figure 27: Attach Pedestal to Pole 6. Slide the scanner onto the p

Seite 26 - SCAN VOLUME

28 EAS DEACTIVATION ANTENNA SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. Metrologic recommends

Seite 27 - ASED ON 100% UPC BAR CODES)

29TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-387

Seite 28

30 TROUBLESHOOTING GUIDE SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Scanning a particular symbology that is not enabled. UPC/EAN, Code 39, interleaved 2

Seite 29 - Installation

31TROUBLESHOOTING GUIDE SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The bar code may have been printed incorrectly. Check if it is a check digit/character

Seite 30

32 TROUBLESHOOTING GUIDE SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Everything works except for a couple of characters. These characters may not be suppo

Seite 31 - FLEX STAND INSTALLATION

33TROUBLESHOOTING GUIDE SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The host is receiving data but the data does not look correct. The scanner and host ma

Seite 32 - EAS DEACTIVATION ANTENNA

34 DESIGN SPECIFICATIONS MS7320 SERIES DESIGN SPECIFICATIONS OPERATIONAL Light Source: Visible Laser Diode (VLD) @ 650 nm Laser Power: 0.678 mW

Seite 33 - TROUBLESHOOTING GUIDE

35DESIGN SPECIFICATIONS MS7320 SERIES DESIGN SPECIFICATIONS ELECTRICAL Input Voltage: 5.2VDC ± 0.25V Power: 1.9 W Operating Current: 360 mA DC

Seite 34

iiiTABLE OF CONTENTS Default Settings ... 40 Scanner

Seite 35

36 RS232 DEMONSTRATION PROGRAM If an RS232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test t

Seite 36

37APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER VER

Seite 37

38 CONFIGURATION MODES The MS7320 has three modes of configuration. • Bar Codes The MS7320 can be configured by scanning the bar codes included

Seite 38 - DESIGN SPECIFICATIONS

39UPGRADING THE FIRMWARE The MS7320 is part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires, a

Seite 39

40 DEFAULT SETTINGS Many functions of the scanner can be "configured" - that is, enabled or disabled. The scanner is shipped from the fac

Seite 40 - RS232 DEMONSTRATION PROGRAM

41DEFAULT SETTINGS PARAMETER DEFAULT OCIA RS232 LIGHT PEN IBM 46XX KBW USB Spaces High as Code 39  Bars High as Scanned  Space

Seite 41 - APPLICATIONS AND PROTOCOLS

42 DEFAULT SETTINGS PARAMETER DEFAULT OCIA RS232 LIGHT PEN IBM 46XX KBW USB Same Symbol Rescan Timeout: 2000 msecs       Intercharac

Seite 42 - CONFIGURATION MODES

43DEFAULT SETTINGS PARAMETER DEFAULT OCIA RS232 LIGHT PEN IBM 46XXKBW USB 8 Data Bits  7 Data Bits *    Transmit Sanyo ID Chara

Seite 43 - UPGRADING THE FIRMWARE

44 DEFAULT SETTINGS PARAMETER DEFAULT OCIA RS232 LIGHT PEN IBM 46XX KBW USB Bookland 977 (2 digit) Supplemental Requirement       S

Seite 44 - DEFAULT SETTINGS

45DEFAULT SETTINGS Default settings for “Aux” interface The secondary scanner and the MS7320 always communicate via RS232. Data is relayed to the

Seite 45

1INTRODUCTION The MS7320 InVista® offers an outstanding combination of features, versatility, performance, and durability. This fixed mount laser

Seite 46

46 SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS7320 scanner interfaces terminate to 10-pin modular jacks located on the bac

Seite 47

47SCANNER AND CABLE TERMINATIONS Figure 32: Scanner Interface Ports MS732x-37 Keyboard Wedge, Stand-Alone Keyboard or USB MS732x-37 RS232 or

Seite 48

48 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) PowerLink Cable MLPN 59-59xxx* Pin Function 1 Shield Ground 2 RS232

Seite 49 - EFAULT SETTINGS

49SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) PowerLink, Keyboard Wedge MLPN 59-59002 Pin Function 1 Key board Cloc

Seite 50 - Scanner Pinout Connections

50 LIMITED WARRANTY The MS7320 InVista® Series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS7320

Seite 51

51REGULATORY COMPLIANCE SAFETY ITE Equipment IEC 60950-1; EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN: 60825-1:1994+A1+A2 Cau

Seite 52

52 REGULATORY COMPLIANCE SAFETY Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gef

Seite 53 - Keyboard Wedge Adapter Cable

53REGULATORY COMPLIANCE EMC Class A Devices (Continued…) This device complies with part 15 of the FCC Rules. Operation is subject to the followi

Seite 54 - IMITED WARRANTY

54 REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s autho

Seite 55 - SAFETY

55PATENTS For patent information, please refer to www.honeywellaidc.com/patents.

Seite 56

2 SCANNER AND ACCESSORIES BASIC KIT Part # Description MS7320 InVista Series Scanner 00-02407 MetroSelect® Configuration Guide 00-02896 MS7320 I

Seite 57

56 INDEX A Accessories ...2 Adapter...49 Auxiliary...2, 33, 45,

Seite 58

57INDEX M Maintenance...14 Manual...2, 37 MetroSelect ...

Seite 61

January 2008 Printed in the USA 00 - 02896G

Seite 62

3SCANNER AND ACCESSORIES OPTIONAL ACCESSORIES Part # Description AC to DC Power Transformer - Regulated 5.2V@ 1A output 46-46759 120V United Stat

Seite 63

4 INSTALLATION FOR OCIA INTERFACE 1. Turn off the host system. 2. Connect the MVC cable to the 10-pin OCIA interface jack. It is the 2nd round

Seite 64 - 00 - 02896G

5Figure 2: Keyboard Wedge InterfacesINSTALLATION FOR KEYBOARD WEDGE INTERFACE 1. Turn off the host system. 2. Disconnect the keyboard from the

Kommentare zu diesen Handbüchern

Keine Kommentare