Seitenansicht 20
17
INDICATORS
Audible
When the Voyager is in operation, it provides audible feedback. These sounds
indicate the status of the scanner. Eight settings are available for the tone of the
beep (normal, 6 alternate tones and no tone). To change the beeper tone, refer
to the MetroSelect
Single-Line Configuration Guide or MetroSet2’s help files.
One Beep
When the scanner first receives power, the green* LED will turn
on, then the red* LED will flash and the scanner will beep once.
The red LED will remain on for the duration of the beep. The
scanner is ready to scan.
When the scanner successfully reads a bar code, the red LED will
flash and the scanner beeps once (if configured to do so). If the
scanner does not beep once and the red light does not flash, then
the bar code has not been successfully read.
Razzberry Tone
This tone is a failure indicator. Refer to “Failure Modes"
on page 19.
Two Beeps – On Power Up
When a Flash ROM upgrade is needed, the scanner will beep
twice followed by alternating flashes of the green and red LEDs.
Three Beeps - During Operation
When entering configuration mode, the red LED will flash while the
scanner simultaneously beeps three times. The red and green
LEDs will continue to flash while in this mode. Upon exiting
configuration mode, the scanner will beep three times, and the
LEDs will stop flashing.
When configured, 3 beeps can also indicate a communications
timeout during normal scanning mode.
When using one-code-configuration, the scanner will beep three
times (the current selected tone), followed by a short pause then
by a high tone and a low tone. This tells the user that the single
configuration bar code has successfully configured the scanner.
Three Beeps - On Power Up
This is a failure indicator. Refer to “Failure Modes” on page 19.
* In some custom units the standard green LED has been replaced with a blue LED and
the red LED has been replaced with a white LED.